• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title Performance Enhancement of Control Systems with Saturating Actuators
Authors 박종구 ; 최종호
Page pp.380-387
ISSN 1975-8359
Abstract The Conventional-Anti-reset-Windup (CAW) structure gives pretty good performance among the conventional strategies that prevent systems from saturation, but there is no systematic way of designing the control systems. Also, it frequently destabilizes the systems. Moreover, the CAW structure cannot be applied when the output of the saturating actuator cannot be measured. Therefore the CAW structure is modified to accommodate this situation. An effective designing method is proposed to give better performance of the control system. The stability of the control system is also considered. The usefulness of the proposed method is shown by applying this method to a few examples.