• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title A Study on the Temperature Characteristics of Main Coolant Pump for System-integrated Modular Advanced Reactor
Authors 구대현(Gu, Dae-Hyeon) ; 방덕제(Bang, Deok-Je) ; 강도현(Gang, Do-Hyeon) ; 김종인(Kim, Jong-In) ; 조윤현(Jo, Yun-Hyeon)
Page pp.320-326
ISSN 1975-8359
Keywords Canned-motor ; FEM ; Cooling water ; Thermal Analysis ; Heat Transfer
Abstract The canned motor of 3-phase induction is used for main coolant pump(MCP). The type of motor is canned-motor that stator and rotor are welded by sealed can. So, cooling water flows in the air gap of the canned motor as an independent cycling cooling system from the air gap to yoke of the motor to prevent high temperature of stator can and to lubricate bearing. Heat exchange is occurred between cooling water in the air gap and cooling water from the exterior pump to prevent rising of temperature in the motor. I has to analyze the characteristics of can exactly because the loss and the heat in the can are very important to design MCP. Therefore, thermal analysis is studied considering the effect of eddy-current los induced in the can.