Title The Measurement Methods of a Large Light Source Using the Integrating Sphere
Authors 황명근(Hwang, Myung-Keun) ; 이세현(Lee, Se-Hyun)
Page pp.585-587
ISSN 1975-8359
Keywords 광원 ; 신광원 ; 적분구 Light Source ; LS
Abstract In this paper, We studied two methods to measure optical characteristics of an electrodeless light source using the integrating sphere(diameter 1.5m). One is to use a center measurement method and the other is to use a side measurement method. As a result of analysis, a side measurement methode without auxiliary lamp is almost similar against a center measurement with auxiliary lamp to reduce a measurement of an error for luminous flux, luminous efficacy and spectral distribution etc. Therefore, Sample which cannot measured by reason of big size and heavy weight can be measured by a side measurement method.