Title Precision Measurement Technique of DC Voltage/Resistance Ratio
Authors 김규태(Kim, Kyu-Tae) ; 유광민(Yu, Kwang-Min)
Page pp.96-99
ISSN 1975-8359
Keywords 표준 ; 정밀측정 ; 전압 ; 저항 ; 직류비율 ; 누설 ;
Abstract We developed 1:1 resistance ratio measurement system for precision measurement of a series-resistor type dc voltage divider. By using active guard technique and exchange technique, any leakage effects, which are one of the most critical error sources, were successfully removed. The best measurement uncertainty with the developed ratio measurement system was estimated to be approximately 10^{-8} for 10 k{Ω} and 100 k{Ω}.