Title A Theoretical Study on Voltage Drop of Auto-Transformer for Railway Vehicle Base
Authors 유기성(Ki-Seong Yu) ; 김재문(Jae-Moon Kim)
DOI http://doi.org/10.5370/KIEE.2018.67.12.1723
Page pp.1723-1728
ISSN 1975-8359
Keywords Swiss cheese model ; Unsafe acts ; Human errors ; Electric shock accidents
Abstract In order to investigate the voltage drop compensation effect of AT for domestic railway vehicle base, the parameters of AT voltage drop of railroad car base are Z3 (Impedance of feeder line), Xn ( Distance from railroad vehicle to AT to SS), and Dn (distance between both ATs of railway vehicle).In addition, when installed in a SSP for a railway vehicle base, there is no AT and feeder line in the railway vehicle base except for the SSP for the main line and the SSP for the railway vehicle base, so that if zero or ignored, the AC single-phase two- It can be confirmed that it becomes a form.