• 대한전기학회
Mobile QR Code QR CODE : The Transactions of the Korean Institute of Electrical Engineers
  • COPE
  • kcse
  • 한국과학기술단체총연합회
  • 한국학술지인용색인
  • Scopus
  • crossref
  • orcid
Title Sensorless Reactive Current Compensation Technique for Single-Phase Photovoltaic System with RL Load
Authors 송민근(Min-Geun Song) ; 이우철(Woo-Cheol Lee)
DOI https://doi.org/10.5370/KIEE.2023.72.1.71
Page pp.71-78
ISSN 1975-8359
Keywords Photovoltaic Systems; Reactive Current; Full-Bridge Inverter
Abstract The PV (photovoltaic) system can be used with RL loads on the grid side. However, when RL Load is connected, the phase of the grid current and voltage will not match due to the reactive current component. The reactive current generated at this time can be compensated by the inverter. In the case of such a single-phase PV system, a total of two current sensors are used to detect the inverter output current and the RL load current. This paper proposes a compensation technique using one current sensor without using two current sensors in a single-phase photovoltaic power generation system connected with an RL load.